Result

Annual yield: 8,376 kWh · 1,047 kWh/kWp

Annual yield8,376 kWhper year
Yield per kWp1,047 kWh/kWp
Irradiation on the module plane1,305 kWh/m²
Yield by month (kWh)
  1. Jan250
  2. Feb387
  3. Mar730
  4. Apr969
  5. May1,057
  6. Jun1,080
  7. Jul1,061
  8. Aug1,007
  9. Sep829
  10. Oct566
  11. Nov253
  12. Dec187
Annual yield by orientation (same tilt)
OrientationkWh%
east6,51878
south-east7,89394
south8,376100
south-west7,76393
west6,34376
Assumptions, method and sources

Assumptions used

  • Place (PVGIS data): Warszawa (52.23, 21.01)
  • System size (kWp): 8.00 · Module tilt (°): 35 · Orientation: 0° · System losses (%): 14.0

Method

Yield: mean hourly PVGIS irradiation (2005–2023) per month, sun position, transposition to the module plane (Hay–Davies), reflection losses, module temperature and efficiency (Huld model as used by PVGIS), system losses. Hourly year: the 8,760 hours of the PVGIS typical meteorological year (TMY) with the same calculation, scaled per month to the monthly yield above. Self-consumption and battery: balance of every hour of the year. Model assumption: consumption as a smoothed course by time of day (hourly means, without load peaks), generation in hourly values (without fluctuations within the hour). This still overstates self-consumption and self-sufficiency: for 4,700 kWh a year HTW Berlin (Weniger, Tjaden, Quaschning, photovoltaik 10/2012) reports just under 30% self-sufficiency with 5 kWp without a battery and more than 60% with a 6 kWh battery; this model gives about 36% and 68% (Berlin, 35° south, flat consumption; with the smoothed generation used until 21 November 2026 it was 40% and 72%). Results for self-consumption and batteries should therefore be read as an upper bound. Money: yearly cash flows with degradation and price changes; NPV at the stated rate, IRR by bisection.

Sources and data validity

Irradiation data: PVGIS © European Union, 2001–2026, licence CC BY 4.0; values processed (hourly means and hours of the typical year). PVGIS

The values “Mój Prąd programme – application status” are valid until 31.12.2026. Values for the next period are not published yet.

The values “Network charges PGE Dystrybucja S.A. (2026)” are valid until 31.12.2026. Values for the next period are not published yet.

The values “RES, cogeneration and capacity charges (2026)” are valid until 31.12.2026. Values for the next period are not published yet.

The values “Energy prices PGE Obrót S.A. (G11/G12, 2026)” are valid until 31.12.2026. Values for the next period are not published yet.