SOLAR PV · PL · DE · AT
Home battery calculator
How much a battery raises self-consumption and when it pays back – an hourly model of one year from PVGIS data and an own consumption profile.
No investment or tariff advice. The result is an estimate based on the stated assumptions and source data (as of 28.11.2026). Before deciding, compare offers and check terms with the network operator and supplier.
Result
Annual yield: 8,362 kWh · Self-consumption: 17 % · Savings in year 1: 1,518 PLN
Net-billing: exported energy is valued at RCE (negative = 0), the deposit × 1.23 only pays for energy purchased (not network charges), after twelve months up to 30 % of the value is refunded, the rest expires.
The battery payback only needs its cost.
| Capacity | Self-consumption | Self-sufficiency | Benefit per year |
|---|---|---|---|
| no battery | 17 % | 40 % | 0 PLN |
| 2.5 kWh | 26 % | 61 % | 256 PLN |
| 5.0 kWh | 33 % | 79 % | 476 PLN |
| 7.5 kWh | 35 % | 84 % | 539 PLN |
| 10.0 kWh | 36 % | 86 % | 566 PLN |
| 15.0 kWh | 37 % | 88 % | 602 PLN |
Range depending on the consumption profile (flat / evening-weighted: night 25%, day 35%, evening 40% – assumption): self-sufficiency with battery 75–79 %, self-consumption with battery 32–33 %, annual benefit 476–502 PLN. Real consumption varies from day to day, so the result is a range, not a single figure.
The model takes generation from the hours of the typical year but consumption as a smoothed hourly course without load peaks, so it still overstates self-sufficiency (comparison with the HTW Berlin study under “Method”: about 6–8 percentage points). Read the results as an upper bound.
Assumptions, method and sources
Assumptions used
- Place (PVGIS data): Warszawa (52.23, 21.01)
- System size (kWp): 8.00 · Module tilt (°): 35 · Orientation: 0° · System losses (%): 14.0
- Annual consumption (kWh): 3,500 · Consumption profile: flat (every hour the same)
- Electricity prices: 1.09 PLN/kWh
- Usable capacity (kWh): 5.0 · Charge/discharge power (kW): 2.5 · Round-trip efficiency (%): 90
Method
Yield: mean hourly PVGIS irradiation (2005–2023) per month, sun position, transposition to the module plane (Hay–Davies), reflection losses, module temperature and efficiency (Huld model as used by PVGIS), system losses. Hourly year: the 8,760 hours of the PVGIS typical meteorological year (TMY) with the same calculation, scaled per month to the monthly yield above. Self-consumption and battery: balance of every hour of the year. Model assumption: consumption as a smoothed course by time of day (hourly means, without load peaks), generation in hourly values (without fluctuations within the hour). This still overstates self-consumption and self-sufficiency: for 4,700 kWh a year HTW Berlin (Weniger, Tjaden, Quaschning, photovoltaik 10/2012) reports just under 30% self-sufficiency with 5 kWp without a battery and more than 60% with a 6 kWh battery; this model gives about 36% and 68% (Berlin, 35° south, flat consumption; with the smoothed generation used until 21 November 2026 it was 40% and 72%). Results for self-consumption and batteries should therefore be read as an upper bound. Money: yearly cash flows with degradation and price changes; NPV at the stated rate, IRR by bisection.
Sources and data validity
Irradiation data: PVGIS © European Union, 2001–2026, licence CC BY 4.0; values processed (hourly means and hours of the typical year). PVGIS
RCE prices: PSE S.A. (raporty.pse.pl), last 365 days. 28.11.2025–27.11.2026
- Net-billing rules (prosumer, Poland) – Polish RES Act: art. 4b(2) (value = quantity × RCE per settlement period, negative RCE = 0), art. 4c(4) (deposit × 1.23), art. 4c(2)–(3) (deposit only pays for energy purchased), art. 4(5) and art. 4c(5)–(6) (12 months), art. 4(11) pt 2 and (11a) (refund up to 30 % / 20 %), art. 4b(3) (15 years). Ustawa o odnawialnych źródłach energii – tekst jednolity Dz.U. 2026 poz. 68 (ELI)
- Notifying the micro-installation to the DSO (Poland) – Polish RES Act art. 5(1): the prosumer informs the distribution system operator at least 30 days before the planned connection of the micro-installation. The act has no separate procedure for plug-in devices. Ustawa o odnawialnych źródłach energii – tekst jednolity Dz.U. 2026 poz. 68 (ELI)
- Mój Prąd programme – application status – Programme website (as of 20.11.2026): the Mój Prąd 6.0 call is closed (last applications 12.09.2025, assessment ongoing); the fund warns about false reports of a “Mój Prąd 7.0”. A granted subsidy can be entered manually. NFOŚiGW – program Mój Prąd
- Electricity tariff comparison
The values “Mój Prąd programme – application status” are valid until 31.12.2026. Values for the next period are not published yet.
The values “Network charges PGE Dystrybucja S.A. (2026)” are valid until 31.12.2026. Values for the next period are not published yet.
The values “RES, cogeneration and capacity charges (2026)” are valid until 31.12.2026. Values for the next period are not published yet.
The values “Energy prices PGE Obrót S.A. (G11/G12, 2026)” are valid until 31.12.2026. Values for the next period are not published yet.
Germany: § 14a EnWG – lower grid fees for wallbox, heat pump and battery
Controllable consumption devices above 4.2 kW connection capacity (private wallbox, heat pump, air conditioning, battery storage) commissioned since 1 Jan 2024 may be throttled temporarily to as little as 4.2 kW by the grid operator. In return the grid fee is lower:
- Module 1: flat annual reduction set by the grid operator (about 110 to 190 euros a year according to BNetzA, as of 2023), once per metering point.
- Module 2: working price of the grid fee reduced to 40 % (i.e. by 60 %); requires a separate meter.
- Module 3 (since April 2025, only with module 1): time-variable grid fees in three tiers (high, standard, low) in time windows set each year by the grid operator; requires a smart metering system.
The values are in the grid operator price sheet for grid fees. Excluding taxes and VAT. Source: Bundesnetzagentur – controllable consumption devices (§ 14a EnWG)
Frequently asked questions
Is the wholesale price the complete electricity bill?
No. Grid costs, supplier additions and taxes may apply. The calculator uses explicitly entered additions in the selected currency.
Is the BDEW standard load profile used?
No. BDEW terms do not allow this use without consent. The calculation uses a flat profile or an own split into night, day and evening.